NV-M500

Illustration: not a contractual representation.

NV-M mobile storage, on skid

NV-M500, The 250 kW

The replacement for the 200 kVA generator set, with fast charger

  • 450 kWhusable kWh
  • 250 kWAC continuous, 400 V
  • 320 kWmachine charging
  • ≤ 6 tweight

On quotation, contact us for availability

What for

  • A 25 t excavator (450 kWh usable) charged in under 3 h, or two mid-size machines at once.
  • Large sites and industry: 250 kW continuous, 396 A per phase.
  • Hybrid mode: the generator set runs two hours at full load instead of ten at idle.
  • Backup for a building or a process: 250 kW for nearly two hours, seamless switchover.

How long it lasts

LoadAverage powerRuntime per charge
Cabins for 20 people, electric heating15 kW30 h 00
Tower crane + site lighting30 kW15 h 00
Four MIG 400 A sets (40% duty cycle)40 kW11 h 15
6 MIG 500 A + TIG 400 A sets70 kW6 h 26
90 kW concrete pump90 kW5 h 00
2,000 m² office building on backup120 kW3 h 45
Site batching plant200 kW2 h 15

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured. Average power over the shift: a 500 A welding set draws 25 kW while arcing, almost nothing between two beads. The peak (motor start) must stay below rated power: no overload. “no”: above the rated AC power.

Specifications

NV-M500

Capacity500 kWh
Energy delivered per charge450 kWh
Continuous AC power250 kW, 400 V
Max. AC current396 A
Machine charging (DC)320 kW
Guns2 CCS2 guns of 160 kW
Charging the unit43 kW (63 A) or 70 kW (100 A), input ≤ 200 A
AC inputs and outputsPowerlock 400 A; CEE 125 / 63 / 32 / 16 A
FormatForklift skid, 4 lifting eyes; trailer version possible
Weight≤ 6 t
Dimensions L × W × H3 205 × 1 740 × 2 117 mm
Altitude≤ 2,000 m

Common to the whole range

CellsLatest-generation LiFePO4, identical modules; non-recoverable energy below 10%
CoolingBattery liquid-cooled in a closed circuit, ventilated electrical section
Grid230 / 400 V three-phase 4-wire, 50 / 60 Hz, islanded mode; switchover < 20 ms on backup
DC chargerCCS2, 200 to 1,000 V DC, 2 to 250 A per gun; MCS on the large models
OverloadNone: size on the site's peak power
EnvironmentIP54, C4 anticorrosion, −30 to +50 °C, ≤ 95% RH
SafetyAutomatic fire suppression (aerosol; clean agent gas on the 20-foot), emergency stop, insulation monitoring
Service life≥ 6,000 cycles; battery warranty 6 years or 6,000 cycles, converter 3 years
SupervisionTouch screen in English and French, remote control from a computer or a phone
TransportUN 3536 class 9; CE, UN 38.3 and IEC 62619 reports supplied with the order

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured.

How many fills

Machine fills from 20 to 100% per full charge of the unit, for the reference machines.

MachineBatteryFills per charge
Develon DX85RE-7235 kWh2.3
Volvo EWR150 Electric270 kWh2.0
Develon DX160WE-7K380 kWh1.4
Develon DX230LCE-7435 kWh1.2
Volvo A30 Electric450 kWh1.2
Develon DX250LCE-7570 kWh0.9
Volvo A40 Electric540 kWh1.0
Volvo L120 Electric282 kWh1.9

Fill = 80% of the machine's battery, 95% charging efficiency. Battery capacities published by the manufacturers, to be checked against your machine's data sheet. The brands mentioned belong to their respective owners. NV Power Station has no commercial relationship with these manufacturers; their machines are cited as sizing references.

Charging the unit

From 0 to 100%, on the site supply or with a generator set in hybrid mode.

SourcePowerTime
63 A supply43 kW11 h 38
100 A supply70 kW7 h 09
250 A supply70 kW (limited by the unit)7 h 09
400 A supply70 kW (limited by the unit)7 h 09
500 kVA generator set in hybrid mode70 kW (limited by the unit)7 h 09

Time = capacity ÷ charging power, capped by the unit's AC input (70 kW).

In pictures

Road trailer version.
Road trailer version. Illustration: not a contractual representation.
500 kWh unit at final inspection.
500 kWh unit at final inspection. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.
Converter in replaceable drawers.
Converter in replaceable drawers. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.

Your NV-M500, on quotation

Tell us the site's average power and peak, the operating hours, your machines and the supply available: we confirm the model and send you an offer.

Request a quote