NV-C3000

NV-C mobile storage, in a container

NV-C3000, The 3 MWh

20-foot container, ten guns, 2 MW of charging

  • 2,700 kWhusable kWh
  • 500 kWAC continuous, 400 V
  • 2,000 kWmachine charging
  • ≤ 30.5 tweight

On quotation, contact us for availability

What for

  • Charging base for a complete fleet: 2,700 kWh usable, ten machines charging at once.
  • Electric trucks: MCS heavy-truck socket.
  • 500 kW at 400 V for the rest of the site.
  • Large earthworks, quarries, logistics platforms.

How long it lasts

LoadAverage powerRuntime per charge
Cabins for 20 people, electric heating15 kW180 h 00
Tower crane + site lighting30 kW90 h 00
Four MIG 400 A sets (40% duty cycle)40 kW67 h 30
6 MIG 500 A + TIG 400 A sets70 kW38 h 34
90 kW concrete pump90 kW30 h 00
2,000 m² office building on backup120 kW22 h 30
Site batching plant200 kW13 h 30

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured. Average power over the shift: a 500 A welding set draws 25 kW while arcing, almost nothing between two beads. The peak (motor start) must stay below rated power: no overload. “no”: above the rated AC power.

Specifications

NV-C3000

Capacity3,000 kWh
Energy delivered per charge2,700 kWh
Continuous AC power500 kW, 400 V
Max. AC current792 A
Machine charging (DC)2,000 kW
Guns10 CCS2 guns of 200 kW + MCS heavy-truck socket
Charging the unitup to 280 kW on 400 A, or 500 kVA generator set in hybrid mode
AC inputs and outputsPowerlock 400 A × 2 or 800 A; CEE 125 / 63 / 32 / 16 A
FormatISO 20-foot container; low-loader semi-trailer to be sourced locally
Weight≤ 30.5 t
Dimensions L × W × H6 058 × 2 440 × 2 590 mm
Altitude≤ 3,000 m

Common to the whole range

CellsLatest-generation LiFePO4, identical modules; non-recoverable energy below 10%
CoolingBattery liquid-cooled in a closed circuit, ventilated electrical section
Grid230 / 400 V three-phase 4-wire, 50 / 60 Hz, islanded mode; switchover < 20 ms on backup
DC chargerCCS2, 200 to 1,000 V DC, 2 to 250 A per gun; MCS on the large models
OverloadNone: size on the site's peak power
EnvironmentIP54, C4 anticorrosion, −30 to +50 °C, ≤ 95% RH
SafetyAutomatic fire suppression (aerosol; clean agent gas on the 20-foot), emergency stop, insulation monitoring
Service life≥ 6,000 cycles; battery warranty 6 years or 6,000 cycles, converter 3 years
SupervisionTouch screen in English and French, remote control from a computer or a phone
TransportUN 3536 class 9; CE, UN 38.3 and IEC 62619 reports supplied with the order

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured.

How many fills

Machine fills from 20 to 100% per full charge of the unit, for the reference machines.

MachineBatteryFills per charge
Develon DX85RE-7235 kWh13.6
Volvo EWR150 Electric270 kWh11.9
Develon DX160WE-7K380 kWh8.4
Develon DX230LCE-7435 kWh7.4
Volvo A30 Electric450 kWh7.1
Develon DX250LCE-7570 kWh5.6
Volvo A40 Electric540 kWh5.9
Volvo L120 Electric282 kWh11.4

Fill = 80% of the machine's battery, 95% charging efficiency. Battery capacities published by the manufacturers, to be checked against your machine's data sheet. The brands mentioned belong to their respective owners. NV Power Station has no commercial relationship with these manufacturers; their machines are cited as sizing references.

Charging the unit

From 0 to 100%, on the site supply or with a generator set in hybrid mode.

SourcePowerTime
63 A supply43 kW69 h 46
100 A supply70 kW42 h 51
250 A supply170 kW17 h 39
400 A supply280 kW10 h 43
500 kVA generator set in hybrid mode280 kW (limited by the unit)10 h 43

Time = capacity ÷ charging power, capped by the unit's AC input (280 kW).

In pictures

Assembly line: overhead crane and conveyor.
Assembly line: overhead crane and conveyor. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.
DC charging hatch: CCS2 guns and MCS socket.
DC charging hatch: CCS2 guns and MCS socket. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.

Your NV-C3000, on quotation

Tell us the site's average power and peak, the operating hours, your machines and the supply available: we confirm the model and send you an offer.

Request a quote