NV-M250

Illustration: not a contractual representation.

NV-M mobile storage, on skid

NV-M250, The 125 kW

For one machine or a small site, on skid

  • 225 kWhusable kWh
  • 125 kWAC continuous, 400 V
  • 160 kWmachine charging
  • ≤ 3 tweight

On quotation, contact us for availability

What for

  • Charging an 8 to 18 t excavator or a mid-size loader, two 80 kW guns.
  • Site cabins, workshop, site lighting at 400 V, 125 kW.
  • Events: control room, stage and catering on a single grid, silently.
  • Under 3 t: moves on a flatbed or a trailer.

How long it lasts

LoadAverage powerRuntime per charge
Cabins for 20 people, electric heating15 kW15 h 00
Tower crane + site lighting30 kW7 h 30
Four MIG 400 A sets (40% duty cycle)40 kW5 h 38
6 MIG 500 A + TIG 400 A sets70 kW3 h 13
90 kW concrete pump90 kW2 h 30
2,000 m² office building on backup120 kW1 h 53
Site batching plant200 kWno

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured. Average power over the shift: a 500 A welding set draws 25 kW while arcing, almost nothing between two beads. The peak (motor start) must stay below rated power: no overload. “no”: above the rated AC power.

Specifications

NV-M250

Capacity250 kWh
Energy delivered per charge225 kWh
Continuous AC power125 kW, 400 V
Max. AC current198 A
Machine charging (DC)160 kW
Guns2 CCS2 guns of 80 kW
Charging the unit43 kW (63 A) or 70 kW (100 A), input ≤ 200 A
AC inputs and outputsPowerlock 400 A; CEE 125 / 63 / 32 / 16 A
FormatForklift skid, 4 lifting eyes; trailer version possible
Weight≤ 3 t
Dimensions L × W × H2 928 × 1 497 × 1 655 mm
Altitude≤ 2,000 m

Common to the whole range

CellsLatest-generation LiFePO4, identical modules; non-recoverable energy below 10%
CoolingBattery liquid-cooled in a closed circuit, ventilated electrical section
Grid230 / 400 V three-phase 4-wire, 50 / 60 Hz, islanded mode; switchover < 20 ms on backup
DC chargerCCS2, 200 to 1,000 V DC, 2 to 250 A per gun; MCS on the large models
OverloadNone: size on the site's peak power
EnvironmentIP54, C4 anticorrosion, −30 to +50 °C, ≤ 95% RH
SafetyAutomatic fire suppression (aerosol; clean agent gas on the 20-foot), emergency stop, insulation monitoring
Service life≥ 6,000 cycles; battery warranty 6 years or 6,000 cycles, converter 3 years
SupervisionTouch screen in English and French, remote control from a computer or a phone
TransportUN 3536 class 9; CE, UN 38.3 and IEC 62619 reports supplied with the order

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured.

How many fills

Machine fills from 20 to 100% per full charge of the unit, for the reference machines.

MachineBatteryFills per charge
Develon DX85RE-7235 kWh1.1
Volvo EWR150 Electric270 kWh1.0
Develon DX160WE-7K380 kWh0.7
Develon DX230LCE-7435 kWh0.6
Volvo A30 Electric450 kWh0.6
Develon DX250LCE-7570 kWh0.5
Volvo A40 Electric540 kWh0.5
Volvo L120 Electric282 kWh0.9

Fill = 80% of the machine's battery, 95% charging efficiency. Battery capacities published by the manufacturers, to be checked against your machine's data sheet. The brands mentioned belong to their respective owners. NV Power Station has no commercial relationship with these manufacturers; their machines are cited as sizing references.

Charging the unit

From 0 to 100%, on the site supply or with a generator set in hybrid mode.

SourcePowerTime
63 A supply43 kW5 h 49
100 A supply70 kW3 h 34
250 A supply70 kW (limited by the unit)3 h 34
400 A supply70 kW (limited by the unit)3 h 34
500 kVA generator set in hybrid mode70 kW (limited by the unit)3 h 34

Time = capacity ÷ charging power, capped by the unit's AC input (70 kW).

In pictures

Road trailer version.
Road trailer version. Illustration: not a contractual representation.
Site sockets: Powerlock, CEE 125, 63, 32 and 16 A.
Site sockets: Powerlock, CEE 125, 63, 32 and 16 A. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.
Unit open: battery modules on the left, converter and supervision on the right.
Unit open: battery modules on the left, converter and supervision on the right. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.

Your NV-M250, on quotation

Tell us the site's average power and peak, the operating hours, your machines and the supply available: we confirm the model and send you an offer.

Request a quote