NV-C1300

Illustration: not a contractual representation.

NV-C mobile storage, in a container

NV-C1300, The 1.3 MWh

10-foot container, 625 kW and five guns

  • 1,170 kWhusable kWh
  • 625 kWAC continuous, 400 V
  • 800 kWmachine charging
  • ≤ 15.3 tweight

On quotation, contact us for availability

What for

  • A fleet of three to four mid-size machines, or two large machines and a dumper.
  • 625 kW AC: the power reserve for pump and crane starts.
  • 1,170 kWh usable: a day and a half of fleet work between two recharges.
  • Same footprint as the 1,000 kWh, 4 t heavier.

How long it lasts

LoadAverage powerRuntime per charge
Cabins for 20 people, electric heating15 kW78 h 00
Tower crane + site lighting30 kW39 h 00
Four MIG 400 A sets (40% duty cycle)40 kW29 h 15
6 MIG 500 A + TIG 400 A sets70 kW16 h 43
90 kW concrete pump90 kW13 h 00
2,000 m² office building on backup120 kW9 h 45
Site batching plant200 kW5 h 51

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured. Average power over the shift: a 500 A welding set draws 25 kW while arcing, almost nothing between two beads. The peak (motor start) must stay below rated power: no overload. “no”: above the rated AC power.

Specifications

NV-C1300

Capacity1,300 kWh
Energy delivered per charge1,170 kWh
Continuous AC power625 kW, 400 V
Max. AC current990 A
Machine charging (DC)800 kW
Guns5 CCS2 guns of 200 kW
Charging the unitup to 280 kW on 400 A
AC inputs and outputsPowerlock 400 A × 2 or 800 A; CEE 125 / 63 / 32 / 16 A
FormatISO 10-foot container, flatbed and crane or heavy-duty hook-lift truck
Weight≤ 15.3 t
Dimensions L × W × H2 991 × 2 440 × 2 590 mm
Altitude≤ 3,000 m

Common to the whole range

CellsLatest-generation LiFePO4, identical modules; non-recoverable energy below 10%
CoolingBattery liquid-cooled in a closed circuit, ventilated electrical section
Grid230 / 400 V three-phase 4-wire, 50 / 60 Hz, islanded mode; switchover < 20 ms on backup
DC chargerCCS2, 200 to 1,000 V DC, 2 to 250 A per gun; MCS on the large models
OverloadNone: size on the site's peak power
EnvironmentIP54, C4 anticorrosion, −30 to +50 °C, ≤ 95% RH
SafetyAutomatic fire suppression (aerosol; clean agent gas on the 20-foot), emergency stop, insulation monitoring
Service life≥ 6,000 cycles; battery warranty 6 years or 6,000 cycles, converter 3 years
SupervisionTouch screen in English and French, remote control from a computer or a phone
TransportUN 3536 class 9; CE, UN 38.3 and IEC 62619 reports supplied with the order

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured.

How many fills

Machine fills from 20 to 100% per full charge of the unit, for the reference machines.

MachineBatteryFills per charge
Develon DX85RE-7235 kWh5.9
Volvo EWR150 Electric270 kWh5.1
Develon DX160WE-7K380 kWh3.7
Develon DX230LCE-7435 kWh3.2
Volvo A30 Electric450 kWh3.1
Develon DX250LCE-7570 kWh2.4
Volvo A40 Electric540 kWh2.6
Volvo L120 Electric282 kWh4.9

Fill = 80% of the machine's battery, 95% charging efficiency. Battery capacities published by the manufacturers, to be checked against your machine's data sheet. The brands mentioned belong to their respective owners. NV Power Station has no commercial relationship with these manufacturers; their machines are cited as sizing references.

Charging the unit

From 0 to 100%, on the site supply or with a generator set in hybrid mode.

SourcePowerTime
63 A supply43 kW30 h 14
100 A supply70 kW18 h 34
250 A supply170 kW7 h 39
400 A supply280 kW4 h 39
500 kVA generator set in hybrid mode280 kW (limited by the unit)4 h 39

Time = capacity ÷ charging power, capped by the unit's AC input (280 kW).

In pictures

Container labelled for battery transport, UN 3536.
Container labelled for battery transport, UN 3536. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.
Liquid-cooled battery packs.
Liquid-cooled battery packs. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.

Your NV-C1300, on quotation

Tell us the site's average power and peak, the operating hours, your machines and the supply available: we confirm the model and send you an offer.