NV-C1000

Illustration: not a contractual representation.

NV-C mobile storage, in a container

NV-C1000, The 1 MWh

10-foot container, carried by hook-lift truck

  • 900 kWhusable kWh
  • 500 kWAC continuous, 400 V
  • 800 kWmachine charging
  • ≤ 11.2 tweight

On quotation, contact us for availability

What for

  • A 25 t excavator and a dumper charged every day, 900 kWh usable.
  • Four mid-size machines charging simultaneously, 200 kW each.
  • 500 kW at 400 V for a batching plant, a workshop, an industrial site on backup.
  • 11.2 t: moves from site to site on a hook-lift truck.

How long it lasts

LoadAverage powerRuntime per charge
Cabins for 20 people, electric heating15 kW60 h 00
Tower crane + site lighting30 kW30 h 00
Four MIG 400 A sets (40% duty cycle)40 kW22 h 30
6 MIG 500 A + TIG 400 A sets70 kW12 h 51
90 kW concrete pump90 kW10 h 00
2,000 m² office building on backup120 kW7 h 30
Site batching plant200 kW4 h 30

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured. Average power over the shift: a 500 A welding set draws 25 kW while arcing, almost nothing between two beads. The peak (motor start) must stay below rated power: no overload. “no”: above the rated AC power.

Specifications

NV-C1000

Capacity1,000 kWh
Energy delivered per charge900 kWh
Continuous AC power500 kW, 400 V
Max. AC current792 A
Machine charging (DC)800 kW
Guns4 CCS2 guns of 200 kW, MCS socket as an option
Charging the unitup to 280 kW on 400 A
AC inputs and outputsPowerlock 400 A × 2 or 800 A; CEE 125 / 63 / 32 / 16 A
FormatISO 10-foot container, hook-lift truck or flatbed and crane
Weight≤ 11.2 t
Dimensions L × W × H2 991 × 2 440 × 2 590 mm
Altitude≤ 2,000 m

Common to the whole range

CellsLatest-generation LiFePO4, identical modules; non-recoverable energy below 10%
CoolingBattery liquid-cooled in a closed circuit, ventilated electrical section
Grid230 / 400 V three-phase 4-wire, 50 / 60 Hz, islanded mode; switchover < 20 ms on backup
DC chargerCCS2, 200 to 1,000 V DC, 2 to 250 A per gun; MCS on the large models
OverloadNone: size on the site's peak power
EnvironmentIP54, C4 anticorrosion, −30 to +50 °C, ≤ 95% RH
SafetyAutomatic fire suppression (aerosol; clean agent gas on the 20-foot), emergency stop, insulation monitoring
Service life≥ 6,000 cycles; battery warranty 6 years or 6,000 cycles, converter 3 years
SupervisionTouch screen in English and French, remote control from a computer or a phone
TransportUN 3536 class 9; CE, UN 38.3 and IEC 62619 reports supplied with the order

Energy delivered = capacity × 90%. Runtimes calculated on 90% of rated capacity, not measured.

How many fills

Machine fills from 20 to 100% per full charge of the unit, for the reference machines.

MachineBatteryFills per charge
Develon DX85RE-7235 kWh4.5
Volvo EWR150 Electric270 kWh4.0
Develon DX160WE-7K380 kWh2.8
Develon DX230LCE-7435 kWh2.5
Volvo A30 Electric450 kWh2.4
Develon DX250LCE-7570 kWh1.9
Volvo A40 Electric540 kWh2.0
Volvo L120 Electric282 kWh3.8

Fill = 80% of the machine's battery, 95% charging efficiency. Battery capacities published by the manufacturers, to be checked against your machine's data sheet. The brands mentioned belong to their respective owners. NV Power Station has no commercial relationship with these manufacturers; their machines are cited as sizing references.

Charging the unit

From 0 to 100%, on the site supply or with a generator set in hybrid mode.

SourcePowerTime
63 A supply43 kW23 h 15
100 A supply70 kW14 h 17
250 A supply170 kW5 h 53
400 A supply280 kW3 h 34
500 kVA generator set in hybrid mode280 kW (limited by the unit)3 h 34

Time = capacity ÷ charging power, capped by the unit's AC input (280 kW).

In pictures

Container labelled for battery transport, UN 3536.
Container labelled for battery transport, UN 3536. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.
DC charging hatch: CCS2 guns and MCS socket.
DC charging hatch: CCS2 guns and MCS socket. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.
Control door: touch screen, indicator lamps, one breaker per outlet.
Control door: touch screen, indicator lamps, one breaker per outlet. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.

Your NV-C1000, on quotation

Tell us the site's average power and peak, the operating hours, your machines and the supply available: we confirm the model and send you an offer.

Request a quote