Charging electric machines

An electric excavator is no use without electricity on site.

From the NV-M250 to the NV-C3000: two to ten CCS2 guns from 80 to 200 kW, an MCS heavy-truck socket, and the same unit powers the site cabins at 400 V. No grid, no generator set running all night.

DC charging hatch: CCS2 guns and MCS socket.
DC charging hatch: CCS2 guns and MCS socket. Photo taken at the plant, pre-series unit; delivered units carry the NV Power Station livery.

Machine families

Three families, three sizes, and the NV unit recommended to charge one machine of each class every day.

Hydraulic excavators

Small, 1.8 to 5.5 t

Utilities, trenching, networks

Examples
Volvo EC18 / ECR18 / ECR25 Electric, Develon DX20ZE-7, DX23E-7, JCB 19C-1E (15 ou 20 kWh), Hyundai HX19e (32 ou 40 kWh), Hitachi ZX55U-6EB (39 kWh)
On-board battery
15 to 40 kWh
Recommended unit
portable station or NV-M250 · See the portable stations

Medium, 8 to 20 t

General earthworks, roads, urban work

Examples
Develon DX85RE-7 (235 kWh), DX100WE-7, DX160WE-7K (380 kWh), Volvo EWR150 Electric (270 kWh), Hitachi ZX85-6EB (100 ou 133 kWh), Mecalac e12 (150 kWh), Liebherr A 918 E Litronic (194 ou 290 kWh)
On-board battery
100 to 380 kWh
Recommended unit
NV-M500

Large, 21 to 28 t

Heavy earthworks, civil engineering

Examples
Volvo EC230 Electric (264 ou 450 kWh), Develon DX230LCE-7 (435 kWh), DX250LCE-7 (570 kWh)
On-board battery
264 to 570 kWh
Recommended unit
NV-M500

Wheel loaders

Small, 2.2 to 6.1 t

Buckets 0.8 to 0.9 m³

Examples
Volvo L20 / L25 Electric, Wacker Neuson WL20e (14 à 23 kWh), Yanmar V8e (40 ou 53 kWh), Liebherr L 507 E (32 ou 64 kWh)
On-board battery
14 to 64 kWh
Recommended unit
portable station or NV-M250 · See the portable stations

Medium, 14.5 to 17.3 t

Buckets 2.1 to 7 m³

Examples
Volvo L90 Electric
On-board battery
180 kWh
Recommended unit
NV-M250

Large, 19.7 to 21 t

Buckets 3.3 to 5.5 m³

Examples
Volvo L120 Electric
On-board battery
282 kWh
Recommended unit
NV-M500

Dumpers and dump trucks

Compact

Spoil removal on small sites

Examples
Wacker Neuson DW15e (1,5 t), DT05e, DT10e, Mecalac eMDX (6 t de charge, 75 kWh)
On-board battery
14 to 75 kWh
Recommended unit
portable station or NV-M250 · See the portable stations

Articulated, 29 t payload

17.8 m³ body

Examples
Volvo A30 Electric
On-board battery
450 kWh
Recommended unit
NV-M500

Articulated, 39 t payload

24 m³ body

Examples
Volvo A40 Electric
On-board battery
540 kWh
Recommended unit
NV-M500

Battery capacities published by the manufacturers (November 2026), quoted as sizing references, to be checked against your machine's data sheet. The brands mentioned belong to their respective owners. NV Power Station has no commercial relationship with these manufacturers; their machines are cited as sizing references.

Classes and capacities change every season; send us your machine's data sheet and we size with your figures.

Which unit to charge my fleet every day?

My fleet

Assumptions: energy to put back into the unit = machine energy ÷ 0.95 (charging losses); one gun per machine above 40 kWh charging simultaneously, small machines on the 400 V sockets; power drawn per machine = battery ÷ window, capped by the gun; unit charging = capacity ÷ supply power, capped by its AC input. Battery capacities published by the manufacturers, to be checked against your machine's data sheet. The brands mentioned belong to their respective owners. NV Power Station has no commercial relationship with these manufacturers; their machines are cited as sizing references.

  • 456 kWhkWh to deliver to the machines per day
  • 480 kWhkWh to put back into the unit every day

Recommended unit

The NV-M500 covers 94% of the day: acceptable if the machines do not go down to 20% every day.

ModelUsable kWhDays per chargeGunsDC chargingCharging the unitVerdict
NV-M2502250.52160 kWno gridtoo small
NV-M5004500.92320 kWno gridtoo small
NV-C10009001.94800 kWno grid✓
NV-C13001,1702.45800 kWno grid✓
NV-C30002,7005.6102,000 kWno grid✓
NV-C40003,6007.562,000 kWDC✓

Charging the unit

Without grid or generator set, the unit cannot recharge: tell us which charging source is available.

The unit will not be full every morning: plan a 250 A supply (5 h 53) or a 150 kVA generator set.

How many fills, how many days

Machine fills (20 to 100%) per full charge of the unit

Machine (battery)NV-M250225 kWh usableNV-M500450 kWh usableNV-C1000900 kWh usableNV-C13001,170 kWh usableNV-C30002,700 kWh usableNV-C40003,600 kWh usable · MCS, on study
Develon DX85RE-7 (235 kWh)1.12.34.55.913.6
Volvo EWR150 Electric (270 kWh)1.02.04.05.111.9
Develon DX160WE-7K (380 kWh)0.71.42.83.78.4
Develon DX230LCE-7 (435 kWh)0.61.22.53.27.49.8
Volvo A30 Electric (450 kWh)0.61.22.43.17.19.5
Develon DX250LCE-7 (570 kWh)0.50.91.92.45.67.5
Volvo A40 Electric (540 kWh)0.51.02.02.65.97.9
Volvo L120 Electric (282 kWh)0.91.93.84.911.4

Fill = 80% of the machine's battery, 95% charging efficiency. In grey: less than one fill. Fills add up across machines: 2.0 on an excavator and 2.0 on a dumper means one excavator and one dumper, not two of each. The brands mentioned belong to their respective owners. NV Power Station has no commercial relationship with these manufacturers; their machines are cited as sizing references.

Fleet days covered by one charge

Fleet (one charge per machine per day)Energy per dayNV-M250NV-M500NV-C1000NV-C1300NV-C3000NV-C4000
1 excavator (25 t, 435 kWh)366 kWh0.6 d1.2 d2.5 d3.2 d7.4 d9.8 d
1 excavator (25 t) + 1 A30 dumper745 kWh0.3 d0.6 d1.2 d1.6 d3.6 d4.8 d
2 excavators (25 t) + 1 L120 loader970 kWh0.2 d0.5 d0.9 d1.2 d2.8 d3.7 d
3 excavators (25 t) + 2 A30 dumpers1,857 kWh0.1 d0.2 d0.5 d0.6 d1.5 d1.9 d
4 excavators (25 t) + 2 A40 + 2 L1202,850 kWh0.1 d0.2 d0.3 d0.4 d0.9 d1.3 d

In grey: the unit does not cover a day on its own; it then works as a buffer, recharged continuously from the grid or a generator set.

Charging time of the unit itself

UnitUsable63 A (43 kW)100 A (70 kW)250 A (170 kW)400 A (280 kW)500 kVA generator set, hybrid
NV-M250225 kWh5 h 493 h 343 h 343 h 343 h 34
NV-M500450 kWh11 h 387 h 097 h 097 h 097 h 09
NV-C1000900 kWh23 h 1514 h 175 h 533 h 343 h 34
NV-C13001,170 kWh1.3 d18 h 347 h 394 h 394 h 39
NV-C30002,700 kWh2.9 d1.8 d17 h 3910 h 4310 h 43

Charging from 0 to 100%; the AC input is limited to 70 kW on the NV-M and 280 kW on the NV-C. The NV-C4000 recharges through its DC input.

How it works on site

  1. 1

    The unit arrives

    On a flatbed or a hook-lift truck, set down near the machine park. No civil works.

  2. 2

    In the evening, the machines plug in

    CCS2 gun, automatic start: each gun regulates its own charge.

  3. 3

    The unit recharges

    From the site grid, 63 to 400 A, or with the existing generator set running a few hours at full load, or from solar as a top-up.

  4. 4

    During the day, it powers the site

    400 V for the site cabins, the workshop, the batching plant.

10-foot NV-C container.
10-foot NV-C container. Illustration: not a contractual representation.

Your fleet, your sizing

Send us the list of your machines and your working hours: we return the sizing, the site layout plan and an offer.

Request a quote